Seismic Evaluation of Existing Buildings Using ASCE Tier 2 and Tier 3 Procedures (AWO). Group/Site (up to 30 engineers) Member $ E-book (PDF) — Available for Download in the ASCE Library of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE. (Standard, ) American Society of Civil Engineers-ASCE standard ASCE_SEI _ American Society of Civil Engineers _ seismic evaluation and retrofit.

Author: Faegami Tojagal
Country: Mongolia
Language: English (Spanish)
Genre: Environment
Published (Last): 5 November 2013
Pages: 177
PDF File Size: 10.26 Mb
ePub File Size: 9.92 Mb
ISBN: 867-7-52006-626-4
Downloads: 88688
Price: Free* [*Free Regsitration Required]
Uploader: Mikarn

Seismic Evaluation and Retrofit of Existing Buildings (41-17)

The seismic evaluation and retrofit process per ASCE consists of three Tiers including, Tier 1 screening procedure, Tier 2 deficiency-based evaluation procedure, and Tier 3 systematic evaluation procedure. This standard establishes analysis procedures and acceptance criteria, and specifies requirements for foundations and geologic site hazards; components made of steel, concrete, masonry, wood, and cold-formed steel; architectural, mechanical, and electrical components and systems; and seismic isolation and energy dissipation systems.

However, it includes considerable changes and improvements over the predecessors. The webinar discusses in detail the evaluation requirements, performance objectives, seismic hazard levels, on-site investigation requirements, and other steps of a Tier 2 and Tier 3 procedure.

The deficiency-based procedures allow evaluation and retrofit efforts to focus on specific potential deficiencies deemed to be of concern for a specified set of building types and heights.

  DOLOR Y DISFUNCION MIOFASCIAL TRAVELL PDF

Alternatively, a full detailed Tier 3 systematic evaluation can be chosen either after a Tier 1 and Tier 2 evaluation or directly from the beginning. System Requirements for Viewing this Course.

Seismic Evaluation and Retrofit of Existing Buildings () | ASCE

Tier 2 deficiency-based evaluation A brief overview of Tier 1 screening procedure Tier 2 scope, limitation, and procedure Tier 2 general requirements Tier 2 condition assessment Tier 2 analysis methods Tier 2 evaluation outcome Part 4: 411-3 are provided for a variety of building types and seismicity levels in support of the Tier 1 screening process. The systematic procedure, applicable to any building, sets forth a methodology to evaluate the entire building in a rigorous manner.

Procedure and details of Tier 1 screening procedure has been presented in a prior evaluation. It also discusses the limitations of Tier 2 and pros and 4-13 of Tier 2 versus Tier 3.

Tier 3 systematic evaluation Tier 3 scope, limitation, and procedure Tier 3 general requirements Tier 3 data collection Tier 3 analysis methods Tier 3 evaluation outcome Questions. Seismic Evaluation and Retrofit of Existing Buildings This webinar provides a brief introduction to ASCEfollowed by a detailed presentation about Tier 2 deficiency-based evaluation procedure, and Tier 3 systematic evaluation procedure. ASCE Seismic Evaluation and Retrofit of Existing Buildings is rapidly becoming the main standard being used for seismic evaluation and retrofit of existing buildings.

  LA VULNERABILIDAD GLOBAL.GUSTAVO WILCHES-CHAUX PDF

It revises the nonlinear dynamic procedure and changes provisions for steel and concrete aasce, as well provisions as for unreinforced masonry. A Tier 1 screening procedure is usually carried out first to quickly identify potential structural deficiencies, after which a detailed Tier 2 evaluation can be performed focusing on those deficiencies.

Evaluation requirements Performance objectives 41–13 hazard level Level of seismicity As-built information Common building type Part 3: The standard presents a three-tiered process for seismic evaluation according to a range of sace performance levels by connecting targeted structural performance and the performance of nonstructural components with seismic hazard levels.

This new edition, which updates and replaces previous editions of ASCE 41, introduces revisions to the basic performance objectives for existing buildings and to the evaluation of force-controlled actions. Keyword s Codes and Standards;Materials;Structural. Many building officials and jurisdictions have either adopted this standard or in the process of reviewing and adopting it.

Written by